ZWK/WCK-11-240KW cabinet intelligent pressure regulating temperature control box

On-site heat treatment in large-scale installation projects, due to very harsh environmental conditions, and often lack of maintenance technology and accessories, according to this characteristic, we design and produce a versatile, high-performance, high-reliability ZWK temperature control box. ZWK adopts international advanced Inlet temperature program control instrument, with program given function and adaptive control function, can be set and run according to the process temperature curve, the temperature is automatically recorded, can not only ensure product quality, but also extend the heater life. The machine can be with each A kind of heater matching, used for pre-heating and post-weld heat treatment. Output voltage 220V, (0-220V) adjustable voltage


Features:

1, three-button PXR5 series of intelligent microcomputer operating temperature controller
2, self-adjusting PID and fuzzy operation control accuracy of ± 1 °C
3, 8 slopes per point / set temperature, insulation, cooling
4, over-temperature, low temperature alarm indication intuitive and reliable
5, SCR output volume is small, weighing only 240 kg
6, adapt to high altitude installation, maintenance, preheating and hydrogen elimination

performance:
Rated voltage 380V (three-phase four-wire)


Rated power 240KW, 12 temperature control points, 12 recording points, maximum temperature 1000°C

Equipped with automatic temperature recorder can print process temperature curve in real time

Output voltage 0-220V AC Adjustable voltage Can also output 220V AC voltage according to customer demand

The output power of the equipment is 30KW, 60KW, 90KW, 120KW, 180KW, 240KW, 360KW

     Model Description
Hspace=0
 
  
model
 Rated output power
(kw)
 Temperature control point
 Record point
 
ZWK/WCK-30-0101
 30
 1
 1
 
ZWK/WCK-60-0306
 60 3 6
ZWK/WCK-90-0306
 90 3 6
ZWK/WCK-120-0612
 120 6 12
ZWK/WCK-180-0612
 180 6 12
ZWK/WCK-240-0612
 240 6 12
ZWK/WCK-360-1212
 360 12 12
 


The complete metal component heat treatment equipment consists of three parts, namely ceramic electric heater, temperature control box and auxiliary materials.

1. Ceramic electric heater: The heating element is the source of heat when the workpiece is heated. Our company provides you with a variety of models and specifications, they have their own characteristics, performance is not the same. Such as LCD track heaters, SCD-type rope heaters, NJ-type heat frame heaters, etc., generally require the user to choose according to the shape of the heated workpiece, thickness and the desired temperature value.
2. Temperature control box: It is matched with the ceramic electric heater to provide power for the ceramic electric heater and control its working status to achieve the purpose of temperature control. The temperature control box is equipped with a temperature controller to control and measure the temperature of the workpiece. The configured temperature recorder is used to record the temperature curve of the workpiece in real time so that the user can archive the temperature. At present, our company provides users with various models of temperature control boxes, such as ZWK, WCK, RWK series of intelligent temperature program control box, DWK, TCS series computer temperature control box, LWK series temperature control box, etc. The user needs to select the ideal and practical temperature control box according to the heating range, heating process requirements and site requirements.
3. Auxiliary material: mainly KJ-type quick-connected wire (connecting wire between the temperature control box and heater, also used for 36V, 55V, 110V and other heaters in series, and equipped with quick-connect plug), thermocouple (temperature sensor , Used to measure the temperature of the heated workpiece), compensation wire (connection line between the thermocouple and the temperature control box), high temperature insulation cotton aluminosilicate (to prevent heat dissipation).

Use cautions:
   1. The heated workpiece must have a reliable ground.
   2, the heater does not allow overlap.
   3、The thermocouple should be attached to the workpiece reliably.
Note:
   1. The width of the heater should be 8-12 times the wall thickness of the heated object.
   2, according to the needs of users can supply complete sets of lead cables, thermocouples, insulation materials and special temperature control cabinets and capacitive soldering coupler.
   3, power error is ± 3%, shape tolerance is ± 2%.
   4, special specifications can be customized.

 
Copyright©Wujiang Xinsheng Electric Equipment Co., Ltd.  蘇ICP備11054944號(hào)-2   Http:http://www.diguagame.com   
Tel.:0512-63685811  Fax.:0512-63685810   Mob.:13962586530   Add.:Meiyan Development zone,Wujiang city,China
<menuitem id="numvx"><center id="numvx"></center></menuitem>
  • <option id="numvx"></option>
    主站蜘蛛池模板: 日韩欧美亚洲每日更新在线| 博罗县| 免费观看做爰视频| 津市市| 洪泽县| 漂亮人妻洗澡被强公bd| 人妻激情偷乱视频一区二区三区| 日本按摩强伦姧在线观看| 精品国产精品人妻久久无码五月天| 久久久国产精品黄毛片| 中国白嫩丰满人妻VIDEOS| 日本无码一区| 山阴县| 无码人妻一区二区三区一| 欧美另类人妻制服丝袜| 井冈山市| 一个人看的WWW片在线高清中文 | 日韩精品无码一区二区视频| 库伦旗| 苗栗市| 巜人妻公妇の浮中字| 富阳市| 滁州市| 奉节县| 宁远县| 肇源县| 宁化县| 芦溪县| 山阴县| 人人超碰97CAOPOREN国...| 成全动漫视频在线观看免费高清| 镇江市| 英山县| 太仓市| 欧美乱妇高清免费| 依安县| 粉嫩XB粉嫩XB粉嫩XB| 钟祥市| 少妇肉欲系列1000篇| 欧美胖老太牲交大战| 欧美黄色片|